PEM Hydrogen Production Equipment - Reliable China Suppliers & Factory with Advanced Safety Features and Efficiency
💧
High Purity Output
Hydrogen purity reaches ≥99.999% after purification.
⚡
Energy Efficient
DC power consumption is optimized at ≤4.3 kW·h/m³H₂.
⚙️
Flexible Load
Operating load range supports 50% to 100% capacity.
| Model | Hydrogen production (m³/h) | Oxygen production (m³/h) | H₂ Purity - Before (V/V) | O₂ Purity - Before (V/V) | H₂ Purity - After (V/V) | Operating load | Work pressure (MPa) | Working temperature (°C) | DC consumption (kW·h/m³H₂) | H₂ Moisture (g/m³) | H₂ Alkali content (mg/m³) | Alkali concentration |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| HYH-20 | 20 | 10 | ≥99.8% | ≥99.2% | ≥99.999% | 50%-100% | 1.5~2.5 | 95±5 | ≤4.3 | ≤4 | ≤1 | 30% KOH |
| HYH-30 | 30 | 15 | ≥99.8% | ≥99.2% | ≥99.999% | 50%-100% | 1.5~2.5 | 95±5 | ≤4.3 | ≤4 | ≤1 | 30% KOH |
| HYH-60 | 60 | 30 | ≥99.8% | ≥99.2% | ≥99.999% | 50%-100% | 1.5~2.5 | 95±5 | ≤4.3 | ≤4 | ≤1 | 30% KOH |
| HYH-100 | 100 | 50 | ≥99.8% | ≥99.2% | ≥99.999% | 50%-100% | 1.5~2.5 | 95±5 | ≤4.3 | ≤4 | ≤1 | 30% KOH |
| HYH-200 | 200 | 100 | ≥99.8% | ≥99.2% | ≥99.999% | 50%-100% | 1.5~2.5 | 95±5 | ≤4.3 | ≤4 | ≤1 | 30% KOH |
| HYH-300 | 300 | 150 | ≥99.8% | ≥99.2% | ≥99.999% | 50%-100% | 1.5~2.5 | 95±5 | ≤4.3 | ≤4 | ≤1 | 30% KOH |
| HYH-400 | 400 | 200 | ≥99.8% | ≥99.2% | ≥99.999% | 50%-100% | 1.5~2.5 | 54±2 | ≤4.3 | ≤4 | ≤1 | 30% KOH |
| HYH-500 | 500 | 250 | ≥99.8% | ≥99.2% | ≥99.999% | 50%-100% | 1.5~2.5 | 95±5 | ≤4.3 | ≤4 | ≤1 | 30% KOH |
| HYH-600 | 600 | 300 | ≥99.8% | ≥99.2% | ≥99.999% | 50%-100% | 1.5~2.5 | 95±5 | ≤4.3 | ≤4 | ≤1 | 30% KOH |
| HYH-800 | 800 | 400 | ≥99.8% | ≥99.2% | ≥99.999% | 50%-100% | 1.5~2.5 | 95±5 | ≤4.3 | ≤4 | ≤1 | 30% KOH |
| HYH-1000 | 1000 | 500 | ≥99.8% | ≥99.2% | ≥99.999% | 50%-100% | 1.5~2.5 | 95±5 | ≤4.3 | ≤4 | ≤1 | 30% KOH |
| HYH-1200 | 1200 | 600 | ≥99.8% | ≥99.2% | ≥99.999% | 50%-100% | 1.5~2.5 | 95±5 | ≤4.3 | ≤4 | ≤1 | 30% KOH |
| HYH-1500 | 1500 | 750 | ≥99.8% | ≥99.2% | ≥99.999% | 50%-100% | 1.5~2.5 | 95±5 | ≤4.3 | ≤4 | ≤1 | 30% KOH |
| HYH-1800 | 1800 | 900 | ≥99.8% | ≥99.2% | ≥99.999% | 50%-100% | 1.5-2.5 | 95±5 | ≤4.3 | ≤4 | ≤1 | 30% KOH |
| HYH-2000 | 2000 | 1000 | ≥99.8% | ≥99.2% | ≥99.999% | 50%-100% | 1.5-2.5 | 95±5 | ≤4.3 | ≤4 | ≤1 | 30% KOH |
What is the purity of the hydrogen produced by the HYH series?
Before purification, the purity is ≥99.8%. After the purification process, the hydrogen purity reaches a high standard of ≥99.999%.
What is the typical power consumption for these hydrogen generators?
The direct current (DC) power consumption for all models in the HYH series is highly efficient, maintaining a level of ≤4.3 kW·h/m³H₂.
Can the system operate at partial capacity?
Yes, the HYH series is designed with an operating load range of 50% to 100%, allowing for flexible production based on demand.
What type of electrolyte is used in the hydrogen production process?
These models use a 30% KOH (Potassium Hydroxide) alkali solution as the electrolyte.
What are the standard working pressure and temperature?
The standard operating pressure ranges from 1.5 to 2.5 MPa, and the working temperature is generally maintained at 95±5°C (with specific models like HYH-400 operating at 54±2°C).
What is the moisture and alkali content in the output gas?
The hydrogen gas moisture content is ≤4 g/m³, and the hydrogen alkali content is strictly controlled at ≤1 mg/m³.