High-Quality Diesel Generators from China Suppliers - Reliable, Efficient, and Durable Factory Solutions
| Parameter of set (400V 3-phase 4-line 50Hz COSΦ0.8) | ||||||||
|---|---|---|---|---|---|---|---|---|
| Engine Type | Type of Set | Output Power | Rated current | Weight of set | Unit Dimensions(mm) | |||
| KW | KVA | (A) | (Kg) | L | W | H | ||
| WP2.3D33E200 | 30GF | 30 | 37.5 | 54 | 600 | 1600 | 680 | 1200 |
| WP2.3D48E200 | 40GF | 40 | 50 | 72 | 700 | 1700 | 680 | 1250 |
| WP4.1D66E200 | 50GF | 50 | 62.5 | 6 | 900 | 1800 | 750 | 1300 |
| WP4.1D80E200 | 75GF | 75 | 93.4 | 135 | 1200 | 2300 | 750 | 1400 |
| WP4.1D100E200 | 90GF | 90 | 112.5 | 162 | 1250 | 2300 | 750 | 1400 |
| WP4.1D108E200 | 100GF | 100 | 125 | 181 | 1300 | 2400 | 750 | 1400 |
| WP6D152E200 | 120GF | 120 | 150 | 217 | 1350 | 2400 | 750 | 1400 |
| WP6P200E200 | 150GF | 150 | 187.5 | 270 | 1550 | 2500 | 800 | 1500 |
| WP10D238E200 | 200GF | 200 | 250 | 360 | 2000 | 2800 | 1000 | 1650 |
| WP10D320E200 | 300GF | 300 | 375 | 540 | 2400 | 2900 | 1000 | 1650 |
| WP13D440E301 (Common Rail) | 400GF | 400 | 500 | 720 | 4700 | 3700 | 1250 | 1950 |
| 6M33D605E200 | 500GF | 500 | 625 | 900 | 5200 | 3800 | 1250 | 1950 |
| 12M26D748E200 | 600GF | 600 | 750 | 1080 | 5300 | 3800 | 1250 | 2000 |
| 12M26D792E200 | 700GF | 700 | 875 | 1268 | 5350 | 3800 | 1250 | 2000 |
| 12M26D902E200 | 800GF | 800 | 1000 | 1440 | 5380 | 3800 | 1250 | 2000 |
| 12M33D1108E200 | 900GF | 900 | 1125 | 1620 | 5440 | 3800 | 1250 | 2000 |
| 12M33D1210E200 | 1000GF | 1000 | 1250 | 1800 | 5480 | 3800 | 1250 | 2200 |
Frequently Asked Questions (FAQ)
What does "COSΦ0.8" mean in the technical parameters?
COSΦ0.8 represents the power factor of the generator set. It indicates that the actual active power (KW) is 80% of the apparent power (KVA). This is the standard rating factor for most industrial three-phase generators.
How is the Rated Current (A) calculated for these sets?
For a 400V 3-phase system with a 0.8 power factor, the rated current is calculated using the formula: Current (A) = Power (KVA) * 1000 / (1.732 * 400V). For example, a 37.5 KVA set yields approximately 54A.
Are these generator sets compatible with 60Hz power grids?
The specifications listed in this table are strictly rated for 50Hz operations at 1500 RPM. Running them at 60Hz (1800 RPM) requires specific engine modifications and configuration adjustments. Please contact support for 60Hz ratings.
What do the L, W, and H dimensions represent?
L, W, and H represent the Length, Width, and Height of the generator set in millimeters (mm). These are standard physical dimensions of the open-type configuration, crucial for planning installation space and ventilation.
Does the listed weight include fuel and coolant?
No, the weights listed in the table (ranging from 600 Kg to 5480 Kg) represent the dry weight of the generator sets without fuel, lubrication oil, or coolant liquids.