High Reliability & Long Service Life: Built on proven diesel engine platforms with reinforced crankshafts, cylinder blocks and pistons. MTBF exceeds 5,000 hours; engine design life is over 20,000 hours (B-level maintenance interval). Multi-level protection systems keep the genset running around the clock.
Fast Start-up & Emergency Response: Cold start to full-load supply takes 10-30 seconds in auto mode. The AMF controller detects grid failure within 1-3 seconds and starts the genset automatically, keeping critical loads powered.
Wide Power Range: Single-unit output from 20 kW to 3,000 kW. Open, soundproof and containerized configurations available. Supports single-unit or parallel multi-unit operation for capacity expansion.
Low Fuel Consumption: High-pressure common rail / electronic injection technology delivers precise fuel control. Specific fuel consumption reaches 0.205-0.225 L/kWh at 75% load — suitable for extended continuous operation.

    Product & Technical Features

    • hy1-advan-icon1

      Low Noise Design

      • Silent-type enclosure keeps noise at or below 70 dB(A) at 7 m. Anti-vibration base and industrial exhaust muffler reduce both mechanical noise and exhaust noise, suitable for hospitals, data centers and similar sites.
    • hy1-advan-icon2

      Intelligent Control & Remote Monitoring

      • Standard microprocessor controller (ComAp / DSE / others) handles auto start/stop, overload protection, voltage/frequency regulation and fault logging. Optional 4G/Ethernet module supports real-time monitoring via mobile or PC, with alarm notification and remote reset.
    • hy1-advan-icon3

      Multi-Brand Engine Options

      • Compatible with Yuchai, Weichai, Cummins, Perkins, Stamford and other major brands. Selection can be based on budget, local service network and parts availability. We can assist with engine selection.
    • hy1-advan-icon4

      Emission Compliance

      • Meets Tier 4 / Stage IV and above emission standards. EGR or SCR aftertreatment systems are available for projects in urban centers, ports or export markets with stricter requirements.

    Core Advantages

    • hy1-advan1

      Ready to Run

      Fast Deployment  Factory-tested before shipment. Site work is limited to connecting fuel, coolant and electrical cables, which keeps installation time short.

    • hy1-advan2

      Full-Range Load Adaptability

      Stable operation from 25% to 110% load. Handles sudden load steps up to 30% Pn, with voltage recovery within 3 seconds.

    • hy1-advan3

      No Gas Supply Needed

      Pure diesel operation requires no gas pipeline, making the genset usable in remote areas, islands, offshore platforms and construction sites.

    • hy1-advan4

      Stable Paralleling, Flexible Expansion

      DSE/ComAp controllers support up to 32 units in parallel, with load sharing accuracy below 2%. Units can be added or removed to match varying load requirements.

    • hy1-advan5

      Dual-Use

      Main & Standby Power  Works as standby emergency power behind a UPS, or as grid-parallel main power — one unit, two roles.

    • hy1-advan2

      Mature Maintenance Ecosystem

      Major-brand spare parts are readily available. Our maintenance services include scheduled inspections, preventive maintenance and 24/7 emergency response.

    • hy1-advan4

      Special Environment Variants

      High-altitude (up to 4,500 m), marine-grade, explosion-proof and cold-climate (-40°C start) models are available for extreme operating conditions.

    • hy1-advan5

      Full-Process Technical Support

      Services cover load analysis, selection reports, electrical design, commissioning and operator training.

    Product Specifications

    Parameter of set (400V3-phase 4-Iine 50Hz COSΦ0.8)
    Engine Type Type of Set Output Power Rated current Weight of set Unit Dimensions(mm)
    KW KVA (A) (Kg) L W H
    WP2.3D33E200 30GF 30 37.5 54 600 1600 680 1200
    WP2.3D48E200 40GF 40 50 72 700 1700 680 1250
    WP4.1D66E200 50GF 50 62.5 6 900 1800 750 1300
    WP4.1D80E200 75GF 75 93.4 135 1200 2300 750 1400
    WP4.1D100E200 90GF 90 112.5 162 1250 2300 750 1400
    WP4.1D108E200 100GF 100 125 181 1300 2400 750 1400
    WP6D152E200 120GF 120 150 217 1350 2400 750 1400
    WP6P200E200 150GF 150 187.5 270 1550 2500 800 1500
    WP10D238E200 200GF 200 250 360 2000 2800 1000 1650
    WP10D320E200 300GF 300 375 540 2400 2900 1000 1650
    WP13D440E301(Common Rail) 400GF 400 500 720 4700 3700 1250 1950
    6M33D605E200 500GF 500 625 900 5200 3800 1250 1950
    12M26D748E200 600GF 600 750 1080 5300 3800 1250 2000
    12M26D792E200 700GF 700 875 1268 5350 3800 1250 2000
    12M26D902E200 800GF 800 1000 1440 5380 3800 1250 2000
    12M33D1108E200 900GF 900 1125 1620 5440 3800 1250 2000
    12M33D1210E200 1000GF 1000 1250 1800 5480 3800 1250 2200
    more
    less
    Parameter of set (400V3-phase 4-Iine 50Hz COSΦ0.8)
    Engine Type Type of Set Output Power Rated current Weight of set Unit Dimensions(mm)
    KW KVA (A) (Kg) L W H
    SC4H95D2 50GF 50 62.5 90 1200 1800 800 1400
    SC4H115D2 75GF 75 93.4 136 1600 2600 800 1400
    SC4H160D2 100GF 100 125 181 1800 2600 900 1400
    SC7H230D2 150GF 150 187.5 271 2000 2700 1100 1450
    SC9D310D2 200GF 200 250 362 2100 2800 1100 1600
    SC13G355D2 250GF 250 312.5 452 2400 3000 1400 1800
    SC12E460D2 300GF 300 375 543 2500 3000 1400 1800
    SC15G500D2 350GF 350 437.5 633 3500 3400 1450 1950
    SC25G610D2 400GF 400 500 724 3600 3600 1500 2050
    SC25G690D2 450GF 450 562.5 814 4000 3600 1500 2100
    SC27G755D2 500GF 500 625 905 4100 3600 1600 2100
    SC27G830D2 600GF 600 750 1080 4900 3800 1650 2100
    SC33W990D2 700GF 700 875 1260 5500 3900 1700 2100
    SC33W1150D2 800GF 800 1000 1440 6140 4100 1420 2140
    more
    less
    Parameter of set (400V3-phase 4-Iine 50Hz COSΦ0.8)
    Engine Type Type of Set Output Power Rated current Weight of set Unit Dimensions(mm)
    KW KVA (A) (Kg) L W H
    SP15KW 4D24G6 18.5 33.3 550 1500 750 1050
    SP20KW 4D24G7 23 41.4 550 1500 750 1050
    SP25KW 4D24TG2 28 50.4 550 1900 840 1200
    SP30KW 4D24TG0 36 64.8 600 1900 840 1200
    SP40KW YC4D80-D34 53 95.4 600 1900 840 1200
    SP50KW YC4D90Z-D21 60 108 850 1900 1200
    SP50KW YC4D90-D34 60 108 850 1900 840 1200
    SP60KW YC4D105-D34 70 126 1300 2410 900 1350
    SP70KW YC4D120-D31 80 144 1600 2410 900 1350
    SP80KW YC4A140L-D20 95 171 1600 2410 6 1350
    SP100KW YC4A180L-D20 120 216 1600 2410 6 1350
    SP100KW YC4A190-D30 125 225 1600 2410 900 1350
    SP120KW YC6B205L-D20 138 248.4 1600 2410 6 1350
    SP120KW YC6A205-D30 138 248.4 1600 2410 900 1350
    SP150KW YC6A245L-D21 165 297 1600 2850 1000 1450
    SP150KW YC6A245-D30 165 297 1600 2850 1000 1450
    SP160KW YC6A275-D30 185 333 2050 2850 1000 1450
    SP200KW YC6MK350L-D20 235 423 2050 2850 1000 1450
    SP200KW YC6MK350-D30 235 423 2050 2850 1000 1450
    SP250KW YC6MK420L-D20 281 505.8 2100 2850 1050 1700
    SP250KW YC6MK420-D30 281 505.8 2100 2850 1050 1700
    SP300KW YC6MJ500L-D21 334 601.2 2100 2850 1050 1700
    SP300KW YC6K500-D31 335 603 2100 2850 1050 1700
    SP350KW YC6T600L-D22 401 721.8 3000 3300 1200 1850
    SP350KW YC6K600-D30 401 721.8 3000 3300 1200 1850
    SP400KW YC6T660L-D20 441 793.8 3500 3700 1450 2000
    SP400KW YC6T660-D31 441 793.8 3500 3700 1450 2000
    SP450KW YC6TD780-D31 520 936 3500 3700 1450 2000
    SP500KW YC6TD840-D31 561 1009.8 3500 3700 1450 2000
    SP550KW YC6TD900-D31 605 1089 4800 3700 1450 2150
    SP600KW YC6TD1000-D30 668 1202.4 5000 3700 1840 2150
    SP640KW YC6C1070-D31 715 1287 8500 4650 1800 2600
    SP730KW YC6C1220-D31 815 1467 8500 4650 1800 2600
    SP800KW YC6C1320-D31 880 1584 8500 4650 1800 2600
    SP900KW YC6C1520-D31 1016 1828.8 8500 4650 1800 2600
    SP1000KW YC6C1660-D30 1110 1998 11500 5500 2300 2950
    SP1100KW YC12VTD1830-D30 1220 2196 13500 5500 2300 2950
    SP1200KW YC12VTD2000-D30 1345 2421 13500 5500 2300 2950
    SP1350KW YC12VC2270-D31 1520 2736 13500 5500 2300 2950
    SP1500KW YC12VC2510-D31 1680 3024 13500 5500 2300 2950
    SP1700KW YC12VC2700-D31 1805 3249 13500 5500 2300 2950
    SP1800KW YC16VC3000-D31 2005 3609 17000 6700 2700 2900
    SP2000KW YC16VC3300-D31 2250 4050 17000 6700 2700 2900
    SP2200KW YC16VC3600-D31 2405 4329 17000 6700 2700 2900
    more
    less
    Parameter of set (400V3-phase 4-Iine 50Hz COSΦ0.8)
    Engine Type Type of Set Engine power Rated current Weight of set Unit Dimensions(mm)
    (A) (Kg) L W H
    4BA3.9-G2 SP20KW 24KW 43.2 650 1900 840 1250
    4BT3.9-G2 SP30KW 36KW 64.8 850 1900 840 1250
    4BTA3.9-G2 SP50KW 58KW 104.4 1000 2410 900 1400
    4BTA3.9-G11 SP64KW 70KW 126 1200 2410 900 1400
    6BT5.9-G2 SP75KW 86KW 154.8 1500 2410 900 1400
    QSB3.9-G3 SP75KW 79KW 142.2 1500 2410 900 1400
    6BT5.9-G2 SP90KW 96KW 172.8 1550 2410 900 1400
    QSB5.9-G2 SP90KW 96KW 172.8 1550 2410 900 1400
    6BTA5.9-G2 SP100KW 106KW 190.8 1600 2410 900 1400
    6BTAA5.9-G2 SP120KW 120KW 216 1600 2410 900 1400
    QSB5.9-G3 SP120KW 120KW 216 1600 2410 900 1400
    6CTA8.3-G2 SP150KW 163KW 293.4 1600 2410 900 1400
    QSB6.7-G4 SP150KW 168KW 302.4 2050 2850 1000 1500
    6LTAA8.9-G2 SP200KW 220KW 396 2050 2850 1000 1500
    QSL8.9-G3 SP200KW 220KW 396 2050 2850 1000 1500
    NT855-GA SP200KW 231KW 360 2050 2850 1000 1500
    QSNT-G6 SP200KW 243KW 360 2050 2850 1000 1500
    NTA855-G1A SP250KW 264KW 450 2500 3150 1100 2000
    QSNT-G1 SP250KW 291KW 450 2500 3150 1100 2000
    6ZTAA13-G3 SP300KW 340KW 612 2900 3150 1100 2000
    QSZ13-G6 SP300KW 328KW 590.4 2900 3150 1100 2000
    NTA855-G2A SP300KW 312KW 540 2900 3150 1100 2000
    QSNT-G3 SP320KW 358KW 576 3200 3150 1100 2000
    6ZTAA13-G2 SP350KW 390KW 702 3200 3150 1100 2000
    QSNT-G4X SP360KW 407KW 648 3200 3150 1100 2000
    QSZ13-G3 SP400KW 450KW 810 3200 3700 1430 2115
    KTA19-G3A SP400KW 448KW 720 3200 3700 1430 2115
    QSK19-G13 SP400KW 451KW 720 3200 3700 1430 2115
    KTAA19-G6A SP500KW Standby 610KW 900 4600 3700 1550 2215
    QSK19-G4 SP520KW 574KW 936 4600 3700 1430 2215
    QSK19-G11X SP550KW 606KW 990 5000 3700 1430 2215
    KTA38-G2 SP600KW 664KW 1080 5800 4400 1800 2500
    QSK38-G8 SP600KW 657KW 1080 6000 4400 1800 2500
    KTA38-G2B SP640KW 711KW 1152 6500 4400 1800 2500
    KTA38-G2A SP730KW 813KW 1314 6500 4400 1800 2500
    QSK38-G6 SP730KW 791KW 1314 6500 4400 1800 2500
    KTA38-G5 SP800KW 880KW 1440 7500 4400 1800 2500
    QSK38-G1 SP800KW 876KW 1440 7500 4400 1800 2500
    KTA50-G3 SP1000KW 1097KW 1800 9000 5000 2200 2600
    QSK38-G5 SP1000KW 1107KW 1800 9000 5000 2200 2600
    KTA50-G8 SP1100KW 1200KW 1980 9500 5000 2200 2600
    QSK38-G19 SP1100KW 1212KW 1980 9500 5000 2200 2600
    KTA50-GS8 SP1200KW 1287KW 2160 9500 5000 2200 2600
    KTA50-G15 SP1350KW 1491KW 2430 9600 5100 2200 2600
    more
    less
    Parameter of set (400V3-phase 4-Iine 50Hz COSΦ0.8)
    Engine Type Type of Set Engine power Rated current Weight of set Unit Dimensions(mm)
    (A) (Kg) L W H
    403D-11G SP7KW 9.5KW 12.6 500 1500 750 1020
    403D-15G SP10KW 13.5KW 18 539 1500 750 1020
    403A-15G2 SP12KW 15.1KW 21.6 580 1500 750 1020
    404D-22G SP16KW 20.6KW 28.8 1500 750 1020
    1103A-33G SP24KW 31KW 43.2 710 1900 840 1230
    1103A-33TG1 SP30KW 46.5KW 54 860 1900 840 1230
    1104D-44TG2 SP50KW 64KW 90 930 1900 840 1250
    1103A-33TG2 SP50KW 60.5KW 6 930 1900 840 1250
    1104C-44TAG2 SP80KW 103KW 144 980 2410 900 1325
    1106A-70TG1 SP100KW 139.9KW 180 1150 2410 6 1425
    1106A-70TAG2 SP120KW 153.5KW 216 1750 2410 6 1425
    1106A-70TAG4 SP160KW 202KW 288 1860 2850 1000 1669
    1206A-E70TTAG2 SP180KW 223KW 324 1880 2850 1050 1670
    1206A-E70TTAG3 SP200KW 245KW 360 1880 2850 1080 1650
    1506A-E88TAG5 SP250KW 293KW 450 2150 3150 1050 1670
    2206C-E13TAG2 SP280KW 305KW 504 3380 3150 1150 2080
    2206D-E13TAG3 SP320KW 349KW 576 3380 3150 1150 2080
    2506D-E15TAG2 SP400KW 435KW 720 3400 3706 1450 2100
    2806D-E18TAG1 SP500KW 522KW 900 3700 3706 1536 2130
    4006-23TAG2A SP600KW 658KW 1080 4500 3930 1560 2380
    4006-23TAG3A SP640KW 705KW 1152 4500 3930 1560 2380
    4008TAG2 SP800KW 899KW 1440 8500 4500 1800 2300
    4008-30TAG3 SP900KW 1105KW 1620 8900 4500 1800 2300
    4012-46TWG2A SP1000KW 1113KW 1800 10500 5000 2200 2700
    4012-46TAG2A SP1200KW 1331KW 2160 13400 5200 2250 2700
    4012-46TAG3A SP1350KW 1500KW 2430 14200 5200 2250 2700
    4016TAG2A SP1600KW 1766KW 2880 20000 6000 2250 3150
    4016-61TRG3 SP1800KW 1975KW 3240 21000 6000 2250 3150
    more
    less
    Parameter of set (400V3-phase 4-Iine 50Hz COSΦ0.8)
    Engine Type Type of Set Engine power Rated current Weight of set Unit Dimensions(mm)
    (A) (Kg) L W H
    TADS50GE SP70KW 85.6KW 126 1050 2100 700 1450
    TAD551GE SP80KW 100.3KW 144 1090 2100 700 1450
    TAD750GE SP100KW 130.6KW 180 1150 2100 800 1450
    TAD751GE SP120KW 151KW 216 1500 2500 1020 1450
    TAD752GE SP140KW 183.1KW 252 1600 2500 1020 1450
    TAD753GE SP160KW 202.4KW 288 1700 2520 1060 1530
    TAD754GE SP200KW 250KW 360 1950 2600 1100 1530
    TAD1351GE SP260KW 313KW 468 2450 3100 1150 1600
    TAD1352GE SP280KW 356KW 504 2550 3100 1150 1600
    TAD1354GE SP300KW 372KW 540 2850 3100 1150 1600
    TAD1355GE SP330KW 404KW 594 2950 3100 1150 1600
    TAD1650GE SP360KW 442KW 648 3050 3100 1150 1600
    TAD1651GE SP400KW 484KW 720 3400 3300 1400 1950
    TWD1652GE SP480KW 522KW 864 3500 3350 1400 1950
    TWD1653GE SP520KW 564KW 936 3600 3350 1400 1950
    TWD1645GE SP560KW 675KW 1008 3800 3400 1400 2000
    more
    less

    Basic Operating Principle

    The diesel generator set runs on Grade 0# or -10# diesel fuel. A four-stroke engine cycle (intake → compression → power → exhaust) converts fuel energy into mechanical power, which a synchronous alternator then converts into electricity. The genset includes a diesel engine, AC alternator, cooling system, lubrication system, starting system, exhaust system and automatic control system, all assembled on a common base frame.

    Core System Description

    • Fuel Supply & Injection System: Diesel fuel passes through the fuel filter, is pressurized by the feed pump, and enters the high-pressure injection pump or common rail system before being injected into the cylinders. Modern units use electronic common rail at 180-200 MPa for multi-injection control, which reduces both fuel consumption and emissions.
    • Air Intake & Turbocharging System: Air enters through the air filter, then into the turbocharger driven by exhaust energy to increase charge density and power output. Charge air is then cooled in the intercooler, further improving volumetric efficiency and reducing combustion temperature and NOx emissions.
    • Cooling System: Closed-circuit water cooling: water pump circulates coolant (50% glycol + deionized water) through the engine water jacket and oil cooler. Heat is dissipated via radiator (mechanical fan or remote cooler). Premium models feature dual-circuit cooling for precise temperature control (85±5°C).
    • Lubrication System: Gear-pump forced lubrication for main bearings, connecting rods and camshaft. Dual-filter (centrifugal + paper element) purification. Integrated oil cooler maintains oil temperature (90-110°C), extending oil life and engine longevity.
    • Starting System: Standard 12V/24V electric start motor (3-9 kW rated) with a maintenance-free lead-acid battery. Units of 500 kW and above can use compressed air start or dual electric start. The AMF controller triggers the start sequence when it detects grid failure.
    • Exhaust & Muffling System: Exhaust gas drives the turbocharger, then flows through a flexible bellows expansion joint into the exhaust pipe and a composite industrial muffler (resistive + reactive), reducing exhaust noise to 85 dB(A) or below. DOC or SCR systems are available for stricter emission zones.
    • Automatic Control & Grid Paralleling System: The microprocessor controller monitors voltage, frequency, current, power, temperature and oil pressure, and adjusts the AVR and electronic governor accordingly. On grid failure, it starts the genset and synchronizes to the load automatically. On grid restoration, it transfers back and shuts down after a cooling period. No manual operation is needed. RS485, Modbus and Ethernet communication protocols are supported.
    • Protection System: Standard protection covers overcurrent, short circuit, over/undervoltage, over/underfrequency, reverse power, high coolant temperature, low oil pressure, overspeed and start failure. All faults are logged for post-event review.

     AMF Automatic Mains Failure Switching Principle

    AMF (Automatic Mains Failure) is the control logic at the core of a diesel standby power system. Sequence: 
    • ① Under normal grid conditions, the genset is in hot-standby with the battery on charge. 
    • ② On grid failure, the AMF controller detects the loss within 1 second, issues a start command, and the genset reaches full output within 5-30 seconds. 
    • ③ When voltage and frequency are stable, the ATS opens the mains circuit and closes the genset supply circuit. 
    • ④ After grid restoration, the system waits 60-180 seconds to confirm stability, transfers back to mains via ATS, then runs the genset at no-load for 3-5 minutes before shutdown.
    hy1-about

    Application Scenarios

    • hy1-application1

      Standby Emergency Power

      Hospitals, data centers, financial institutions, transportation hubs and critical government facilities rely on the diesel genset as the last backup behind UPS. When the grid goes down for an extended period, the genset keeps critical equipment running.
    • hy1-application2

      Industrial Park Primary Power

      For remote industrial parks, mines, oil and gas fields and construction sites without reliable grid access. Multiple paralleled gensets serve as the primary power source, with load-tracking control to reduce fuel consumption.
    • hy1-application3

      Mobile Emergency & Rapid Deployment

      Containerized diesel gensets (Type C) are compact and easy to transport. They can be deployed and on-load within 30 minutes, making them a practical choice for disaster relief, military logistics and large temporary events.
    • hy1-application4

      Marine & Offshore Applications

      Marine-class diesel gensets certified by CCS, BV or DNV meet vibration, salt spray and inclination requirements. They are used as main, auxiliary or emergency power on inland vessels, ocean freighters, offshore platforms and port facilities.
    • hy1-application5

      High Altitude & Extreme Environments

      High-altitude models are configured with turbocharger matching, fuel compensation and cold-start heating to deliver rated power up to 4,500 m altitude. Arctic-grade models include full trace-heating for cold starts at -40°C.
    • hy1-application6

      Commercial Complexes & Campuses

      For shopping malls, office buildings, hotels, airports, schools and enterprise campuses as grid backup. The genset transfers automatically on grid failure, keeping operations running. Parallel operation is also available for peak-shaving, which requires a synchronization panel and metering system.

    Have A Project In Mind? Let's Talk.

    We deliver quality, safety, and modern solutions to every project.
    turning visions into strong realities for our clients.

    Follow us:

    Company*

    Name*

    Telephone*

    Interested Products*

    Message*
    GET A QUOTE! hy-plane