Cryogenic Air Separation Plant China Suppliers | Factory High-Purity N2 O2 Ar Production, Energy Efficient, Modular Design

,

• Utilizing advanced cryogenic distillation technology, our system effectively separates air into high-purity N₂, O₂, and liquid argon based on boiling point differences, making it a top choice among China suppliers.
• The system boasts a N₂ capacity of 100 to 50,000 Nm³/h, with N₂ purity levels of ≤3ppm O₂ (99.9997%) and O₂ purity reaching ≥99.6%, satisfying stringent industry standards.
• Featuring a high-efficiency turbo expander and main heat exchanger, our design reduces overall energy consumption by 10% to 20% compared to conventional factory units.
• Fully automated PLC/DCS control ensures optimal performance with load regulation from 30% to 110%, easily adapting to downstream fluctuations.
• The system provides simultaneous output of gaseous and liquid products (LIN, LOX, LAR) along with cryogenic liquid storage tanks for efficient operations.
• With a design life of over 20 years and a continuous operation cycle of at least 2 years, maintenance costs are kept low.
• Our modular design allows for easy installation within a small footprint, making it ideal for on-site centralized gas supply for various industries.

,
    Parameter Specification
    Technology Pressure Swing Adsorption (PSA)
    Adsorbent Carbon Molecular Sieve (CMS)
    Product Gas Nitrogen (N₂)
    Purity 95% - 99.999% (adjustable)
    Capacity 1 - 3000 Nm³/h (single unit)
    Working Pressure 0.6 - 0.95 MPa
    Outlet Pressure 0.1 - 0.6 MPa (adjustable)
    Dew Point ≤ -40℃
    Control Fully automatic PLC with touchscreen HMI

    Nitrogen is produced within 10-15 minutes

    I. Small Cryogenic Air Separation Unit — Technical Specifications
    Model KDON-50/50 KDON-80/160 KDON-180/300 KDON-260/500 KDON-350/700 KDON-550/1000
    O₂ Output Nm³/h 50 80 180 260 350 550
    O₂ Purity %O₂ ≥99.6 ≥99.6 ≥99.6 ≥99.6 ≥99.6 ≥99.6
    N₂ Output Nm³/h 50 160 300 500 700 1000
    N₂ Purity ppm O₂ ≤10 ≤10 ≤10 ≤10 ≤10 ≤10
    Unit Energy KWh/Nm³O₂ ≤1.3 <0.85 ≤0.68 ≤0.65 ≤0.65 ≤0.65
    Footprint m² 145 150 160 180 250 420
    II. High-Purity Nitrogen (Cryogenic) Unit — Technical Specifications
    Model KDN-200 KDN-300 KDN-400 KDN-700 KDN-1000 KDN-1600
    N₂ Output Nm³/h 200 300 400 700 1000 1600
    N₂ Purity ppm O₂ ≤3 ≤3 ≤3 ≤3 ≤3 ≤3
    LN₂ Output L/h / 10 10 20 40 60
    N₂ Pressure MPa 0.34~1 0.34~1 0.34~1 0.34~1 0.34~1 0.34~1
    Footprint m² 95 150 220 260 300 320
    III. Liquid Cryogenic / Liquefaction Unit — Technical Specifications
    Model KDO-180y KDO-250y KDO-400y KDON-1200y/300y KDONAr-1300y/200y/40y
    LO₂ Output Nm³/h 180 400 400 1200 1300
    LO₂ Purity % ≥99.6 ≥99.6 ≥99.6 ≥99.6 ≥99.6
    LO₂ Pressure MPa 0.2 0.2 0.2 0.2 0.2
    LN₂ Output Nm³/h — — — 300 200
    LN₂ Purity PPm O₂ — — — ≤5 ≤5
    LN₂ Pressure MPa — — — 0.5 0.5
    LAr Output Nm³/h — — — — 40
    LAr Purity — — — — ≤1.5ppm O₂+4ppm N₂
    LAr Pressure MPa — — — — 0.2
    Footprint m² 250 300 350 850 4000
    IV. Physical Properties of Air Components (Table 1) — Composition
    Component Symbol Volume Fraction % Weight Fraction %
    Nitrogen N₂ 78.084 75.5
    Oxygen O₂ 20.95 23.1
    Argon Ar 0.932 1.29
    Carbon Dioxide CO₂ 0.035 0.05
    Helium He 0.00046 0.00006
    Neon Ne 0.0016 0.0011
    Krypton Kr 0.00011 0.00032
    Xenon Xe 0.000008 0.00004
    V. Physical Properties of Air Components (Table 2) — Physical Data
    Component Symbol Boiling Pt. ℃ Melting Pt. ℃ Gas Density Kg/m³ Liquid Density Kg/L Critical Temp. ℃ Critical Pressure MPa(G)
    Nitrogen N₂ -195.8 -209.86 1.2506 0.81 -147 3.45
    Oxygen O₂ -183 -218.4 1.4289 1.14 -119 5.13
    Argon Ar -185.7 -189.2 1.784 1.4 -122 4.959
    Helium He -268.9 -272.55 0.18 0.125 -267.7 0.2335
    Neon Ne -246.1 -248.6 0.748 1.204 -228.7 2.813
    Krypton Kr -153.2 -157.2 1.735 2.155 -63.7 5.6
    Xenon Xe -108 -111.8 1.664 3.52 16.6 6.01
    Frequently Asked Questions (FAQ)
    What is the oxygen purity standard for Small Cryogenic Air Separation Units?
    All models of our Small Cryogenic Air Separation Units (from KDON-50/50 to KDON-550/1000) produce oxygen with a purity level of ≥99.6% O₂, meeting high industrial and medical specifications.
    What is the nitrogen purity level for High-Purity Nitrogen Units?
    The KDN series High-Purity Nitrogen (Cryogenic) Units guarantee an oxygen content of ≤3 ppm O₂, ensuring ultra-high purity nitrogen output suitable for electronics, chemical processing, and packaging industries.
    Can Liquid Cryogenic Units produce liquid argon?
    Yes, specific liquefaction models such as the KDONAr-1300y/200y/40y are designed to produce Liquid Argon (LAr) with a purity level of ≤1.5ppm O₂ + 4ppm N₂ at a rate of 40 Nm³/h.
    What are the primary boiling points of main air components?
    Based on physical properties data, Nitrogen (N₂) has a boiling point of -195.8 ℃, Oxygen (O₂) has a boiling point of -183 ℃, and Argon (Ar) boils at -185.7 ℃. These differing boiling points facilitate separation via cryogenic distillation.
    How much space is required to install these cryogenic units?
    The footprint depends on the unit type and capacity. High-purity nitrogen units require between 95 m² to 320 m², small gaseous air separation units require 145 m² to 420 m², while larger liquid liquefaction plants can require up to 4000 m².

    Have A Project In Mind? Let's Talk.

    We deliver quality, safety, and modern solutions to every project.
    turning visions into strong realities for our clients.

    Follow us:

    Company*

    Name*

    Telephone*

    Interested Products*

    Message*
    GET A QUOTE! hy-plane